10
Technical data
10.1
MAX
®
Analog / PWM
For details of applied tests and descriptive standards, please see document 8021472.
Table 41: Technical data - MAX
®
Analog / PWM
Performance
Measurand
Position
Measuring range
Position (F.S.
2)
) MAX48N/MAX48A: 0050 … 2,500 mm (in 1 mm increments)
MAX30N: 0050 ... 1,500 mm (in 1 mm steps)
Unusable range
Null zone (zero point) MAX48N/MAX48A: 30.0 mm
MAX30N: 21.5 mm
Damping
zone (end point)
30.0 mm/ 36.0 mm/ 63.0 mm (depending on type)
Power-up delay
< 250 ms
Measuring frequency (internal)
2 ms
Setpoint tolerance
Zero point and F.S.
2)
≤ 1.0 mm
Resolution
0.1 mm typical (noise-free)
Hysteresis
± 0.1 mm
Repeatability
Typ. ± 0.2 mm
Linearity (in operational status)
Typ. ± 0.25 mm (measuring range from 50 to 500 mm)
Typ. ± 0.04% F.S. (Measuring range from 500 to 2,500 mm)
Temperature drift
Self-heating of the electronics (warm-up phase) Typ. ≤ ± 0.25 mm (2 min)
Operational status (hydraulic oil at operating tem‐
perature)
≤ ± 0.005% x F.S. x ΔT (ΔT 40 °C)
3)
MTTFd
69 years (EN ISO 13849-1)
4)
5)
Interfaces
Analog
PWM
Communication interface detailed
Voltage / current
PWM
Voltage output
0.25 ... 4.75 V
0.50 ... 4.50 V
0.50 ... 9.50 V
1.00 ... 9.00 V
9.50 ... 0.50 V
9.00 ... 1.00 V
4.75 ... 0.25 V
4.50 ... 0.50 V
-
Current output
4.00 ... 20.00 mA
20.00 ... 4.00 mA
-
2)
F.S. = Full scale (measuring range end value)
3)
Rise in oil temperature by 40 °C during operation
4)
69 years (EN ISO 13849-1)
5)
Every 2nd
failure of an electronic component is considered hazardous.
10
TECHNICAL DATA
48
O P E R A T I N G I N S T R U C T I O N S | MAX
®
8022793/1EFT/2021-12-15
| SICK
Subject to change without notice