1
2
3
4
Figure 10: Detailed view of installation cavity for encoder housing
1
Bore hole for passing through the electrical connecting cable
2
Installation cavity for encoder housing (d2 and T2)
3
Threaded hole for the retaining screw
4
Diameter (d1) and depth (T1) of electrical connection
4.2.2
Insertion chamfer
To ensure proper and secure installation of the device in the cylinder, a insertion
chamfer must be provided.
NOTICE
Risk of damage to the device during installation
The device can be damaged by any sharp edges present at the transition from the
cylinder bore hole to the insertion chamfer on the O-ring.
b
Prepare an insertion chamfer with a radius of 0.6 mm at the end of the cylinder
bore hole.
4
MOUNTING
16
O P E R A T I N G I N S T R U C T I O N S | MAX
®
8022793/1EFT/2021-12-15
| SICK
Subject to change without notice