Ambient data
Noise (resonance peaks removed) MAX48N/MAX48A: 20 g (r.m.s), 48 h / spatial axis, 10 ... 2,000 Hz (IEC
60068-2-64)
MAX30N: 15 g (r.m.s), 48 h / spatial axis, 10 ... 2,000 Hz (IEC
60068-2-64)
Nominal operating pressure (PN)
MAX48N/MAX48A: 400 bar
MAX30N: 320 bar
Max. overload pressure during operation (PN x
1.2)
MAX48N/MAX48A: 480 bar
MAX30N: 380 bar
Max. test pressure in cylinder (PN x 1.5)
MAX48N/MAX48A: 600 bar
MAX30N: 480 bar
10.3
Encoder dimensions
MAX48N
2
3
1
3
L ±1.0
(0.04)
27.2
(1.07)
21.2
(0.83)
Ø 48f7
(1.89)
Ø 24
(0.94)
11.5
(0.45)
30
(1.18)
Ø 10
(0.39)
Figure 39: MAX48N housing without connecting cable / strands
1
Measuring range
2
Damping zone
3
Position magnet
MAX48A
3
3
1
2
4
30
(1.18)
29.75
(1.17)
L ± 1.0
(0.04)
Ø 24
(0.94)
Ø 10
(0.39)
21.2
- 0.2
(0.83 - 0.01)
11.5
± 0.2
(0.45 ± 0.01)
Ø 48f7
(0.94)
Figure 40: MAX48A housing with M12 male connector / strands
1
Measuring range
2
Damping zone
3
Position magnet
4
Strand length
10
TECHNICAL DATA
54
O P E R A T I N G I N S T R U C T I O N S | MAX
®
8022793/1EFT/2021-12-15
| SICK
Subject to change without notice