13
Technical data
13.1
Variant overview
Ordering information:
see "Ordering information", page 135
Table 18: Devices and type codes
Performance package
Integration in the control
Protective field
range
Device without system
plug
System plug
Device with system plug
•
Core
•
I/O AIDA
≤ 4.0 m
MICS3-AAAZ40BZ1
MICSX-ABHZZZZZ1
MICS3-AAAZ40BZ1P01
≤ 5.5 m
MICS3-AAAZ55BZ1
MICS3-AAAZ55BZ1P01
≤ 9.0 m
MICS3-AAAZ90BZ1
MICS3-AAAZ90BZ1P01
13.2
Version numbers and functional scope
Functional scope
Older devices might not support the full functional scope of the latest Safety Designer.
To identify the different levels of the functionality, we use a 3-digit version number. The
version number is marked with the letter V on the device.
The functional scope of the device can be read at the following locations:
•
Label on the device
•
Display, entry in
Device info
menu at
Hardware
•
Safety Designer,
Overview
dialog (only with connected device)
•
Safety Designer, report
Table 19: Functional scope of the microScan3 Core I/O AIDA
Version number
Amendments and new functions
1.0.0
•
First released version
1.1.0
•
New rights management using user group
Administrator
(now 4
user groups)
•
Additional third option for resetting to factory settings
•
Modified process for resetting the password
•
Deviating multiple sampling after object detection can be con‐
figured
•
Interfaces and selected functions can be activated or deacti‐
vated
Revision
The different revision statuses of the devices are identified by “Rev” followed by a three-
digit version number. New devices have a label which indicates the revision status.
Table 20: Revision
Version number
Amendments and new functions
1.0.0
•
First released version
1.1.0
•
Internal change to components, no change in function
1.2.0
•
Internal change to components, no change in function
1.3.0
•
Adaptation of detection behavior for optimized safety and avail‐
ability
In some cases, new system plugs are not suitable for older devices.
New system plugs have a label which indicates the devices for which they are suitable.
TECHNICAL DATA
13
8017784/1ELL/2022-01-21 | SICK
O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA
125
Subject to change without notice