18.4
Mounting methods for protection from interference from systems in close proxim‐
ity
Mutual interference of several safety laser scanners is unlikely thanks to the safeHDDM
scanning technology. You can choose a suitable mounting method to guarantee partic‐
ularly high availability or to avoid interference with laser scanners that do not have
safeHDDM functionality. In many cases, you can use the following examples as a guide.
NOTE
You must comply with the standard ISO 13855 when choosing the mounting method.
Mount several safety laser scanners offset and parallel to one another
≥
100 mm
Figure 76: Mounting 2 safety laser scanners with the optics cover facing upward
≥
100 mm
Figure 77: Mounting 2 safety laser scanners with the optics cover facing downward
18
ANNEX
144