d
r
= coarsest permissible resolution of the safety laser scanner in millimeters
(mm)
•
H
D
= height of the protective field above the floor in millimeters (mm)
b
The safety laser scanner’s resolution can be set to the predefined value d. If the
result d
r
does not match any of these values, choose a finer resolution (d ≤ d
r
).
4.3.5.4
Distance from walls
Overview
The availability may be impaired if the protective field stretches as far as a wall or a
different object. So, plan to have a space between the protective field and the object. A
distance of the TZ value is recommended to ensure availability. (TZ = tolerance range of
the safety laser scanner,
1
Figure 24: Distance of the protective field from the wall
1
Recommended distance of the protective field from the wall.
Important information
DANGER
Hazard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of
non-observance.
If the distance between the protective field and the wall is so large that a person can
stand in it, this person might not be detected. If needed, take suitable measures to
prevent this such as:
b
Attaching deflector plates
b
Attaching fence
4
PROJECT PLANNING
34
O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA
8017784/1ELL/2022-01-21 | SICK
Subject to change without notice