At first, the object resolution and multiple sampling configured for the monitoring plane
apply for all fields. If necessary, make changes to each individually at a later date. If you
do this, Safety Designer will indicate this in the settings for the monitoring plane.
Name
You can use the name to identify monitoring planes when creating fields and monitoring
cases and also in reports.
b
Enter a descriptive name for the monitoring plane (e.g., “Hazardous area on the
right hand side”).
✓
The name is used to identify the monitoring planes.
Safety task
People approach the monitoring plane parallel or orthogonally, depending on the orien‐
tation of the protective field in your application (
see "Project planning", page 20
).
•
Hazardous area protection (Horizontal)
Typically, for a horizontal approach, the requirement is to detect the leg. The typical
object resolution is leg (70 mm).
•
Access protection (Vertical)
Typically, for access protection, the requirement is to detect a person. The typical
object resolution is body (200 mm).
•
Hazardous point protection (Vertical)
Typically, for hazardous point protection, the requirement is to detect a hand. The
typical object resolution is hand (40 mm).
Reference contour monitoring
NOTE
If the monitoring plane has a vertical alignment, a contour (such
as the floor, a part of
the machine bed, or an access threshold) must typically be defined and monitored as
a reference contour. A reference contour field is used for this,
b
Activate the
Reference contour monitoring
option.
✓
The
item is shown in the navigation. Here you can configure
the reference contour field required for your application.
Object resolution
The object resolution defines the size that an object must be to allow it to be reliably
detected. The following object resolutions are available:
•
30 mm = hand detection
•
40 mm = hand detection
•
50 mm = leg detection/arm detection
•
60 mm = leg detection/arm detection (depends on variant)
•
70 mm = leg detection/arm detection
•
150 mm = body detection
•
200 mm = body detection
b
Choose the object resolution.
✓
Objects the same size as or larger than the chosen object resolution are reliably
detected.
CONFIGURATION
7
8017784/1ELL/2022-01-21 | SICK
O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA
75
Subject to change without notice