User group
Password
Authorization
Authorized client Deactivated ex-works, i.e. it is
not initially possible to log on as
an authorized customer. The user
group can be activated by the user
group administrator and provided
with a password.
•
May read configuration from the
device.
•
May transmit verified and
unverified configuration to the
device.
•
May verify configuration.
•
Resetting the safety function
and communication settings to
factory defaults is allowed.
•
Change own password allowed.
•
Changing the password of the
Maintenance personnel
user group
is allowed.
Administrator
The password SICKSAFE is created
at the factory.
b
Change this password to pro‐
tect the device against unau‐
thorized access.
•
May read configuration from the
device.
•
May transmit verified and
unverified configuration to the
device.
•
May verify configuration.
•
Resetting whole device to fac‐
tory settings allowed.
•
Activating and deactivating
device functions is allowed.
•
Activating and deactivating the
Maintenance personnel
and
Author‐
ized client
user groups is
allowed.
•
Change own password allowed.
•
Changing the passwords of
the
Maintenance personnel
and
Authorized client
user groups is
allowed.
Complementary information
The maintenance engineer is permitted to reset the safety function to factory settings.
The configuration of the device is saved in the system plug. Therefore, the passwords
are retained when the device is replaced if the system plug is still used.
Further topics
•
"Version numbers and functional scope", page 125
7.2.5
Settings
Information on the functionality and basic operation of the software and on the settings
in the main window can be found in the operating instructions of the Safety Designer
(part number 8018178).
7.2.6
Configuration
You collect the devices of a project in the
Configuration
area. The available devices can
be found in the Device Catalog. The devices are displayed as Device tiles in the working
range.
7
CONFIGURATION
66
O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA
8017784/1ELL/2022-01-21 | SICK
Subject to change without notice