Operating Instructions
Chapter
3
CLX 490
8 009 237/0000/07-05-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
3-1
Product description
3
Product description
3.1
Design
3.1.1
Scope of delivery
The CLX is supplied with the following in the
packing
:
•
an information sheet (notes on device) with terminal diagram and Quick Start
instructions
•
an additional set of Class 2 laser warning labels (self-adhesive) in German/US English
and French/US English
Depending on
the number of devices ordered
, one or more
sets of technical documen-
tation
comprising:
•
These CLX 490 Operating Instructions in English and German
•
A CD-ROM containing the "CLV-Setup" program for Windows
TM
, the CLV-Setup Help on-
line help system, and the I-ViewPro
TM
HTML browser
Chapter 10.12 Accessories, Page 10-33
contains an overview of the available accessories,
connection modules, cables, and connectors, as well as sensors for generating the reading
pulse.
3.1.2
Variants
The CLX is currently available in the following variants:
Tab. 3-1: CLX variants
3.1.3
System requirements
CLX without heater
The following are required to start up and operate the CLX without heater:
1.
A SICK Connection Module to provide the power supply and connect the data and func-
tion interfaces.
Available types:
– For connecting
one
CLX:
AMV 60-011 (no. 1 017 134) for 18 ... 30 V DC, enclosure rating max. IP 54
AMS 60-013 (no. 1 017 139) for 230 V AC 50 Hz/24 V DC,
enclosure rating max. IP 54
AMS 60-012 (no. 1 017 140) for 115 V AC 50/60 Hz/24 V DC,
enclosure rating max. IP 54
AMV 100-011 (no. 6 021 105) for 18 ... 30 V DC, enclosure rating max. IP 65
– For connecting
two
CLX:
AMV 30-071 (no. 1 017 391) for 18 ... 30 V DC, enclosure rating max. IP 54
AMV 200-011 (no. 6 021 106) for 18 ... 30 V DC, enclosure rating max. IP 65
– or –
Alternatively, a non-SICK Power pack with a voltage output of 18 ... 30 V DC pursuant
to IEC 742 (functional extra-low voltage) and a minimum power output of
20 W
.
Cable no. 2 020 264 (3 m) with 15-pin D Sub HD connector and one open end for
connecting the CLX to the non-SICK Power pack (supply voltage).
Type (red light)
Part. no.
Scanning method
Resolution
Heater
CLX 490-0010
1 019 318
Compact OMNI Scanner
from 0.30 mm
no
CLX 490-0011
1 019 319
Compact OMNI Scanner
from 0.30 mm
yes