Operating Instructions
Chapter
3
CLX 490
8 009 237/0000/07-05-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
3-9
Product description
CLX with external parameter memory connected
Operating mode LED
Display
Function
Start
Device Ready
Green
•
Lights up after power-up if the self-test was successful
Subsequent behavior depends on selected start option:
Start option: S
TART
WITH
EXTERNAL
P
ARAMETERS
(default):
•
Blinks for approx. 10 s before lighting up constantly
(CLX has loaded the parameter set from the external parameter
memory and starts reading mode straight away)
•
Blinks for approx. 10 s together with the "Read Result" LED, then lights up
constantly.
(CLX has loaded the parameter set from the external parameter memory with
tolerated errors
1)
and starts reading mode straight away)
•
Lights up constantly
(CLX could not find an external parameter memory and loads the internal para-
meter set instead)
•
Blinks constantly together with the "Read Result" LED
2)
(The external parameter memory is either empty, contains the parameter set for
another CLX type, or is corrupt)
CLX has loaded the internal parameter set. It starts Reading mode but does not
output data over the host interface)
Start option: S
TART
WITH
INTERNAL
P
ARAMETERS
:
•
Lights up constantly (CLX has loaded internal parameter set)
Start option: S
TART
WITH
C
OPY
I
NTERN
-> E
XTERN
:
•
Blinks alternately with the "Read Result" LED for approx. 10 s before lighting
up constantly
(CLX has successfully copied the internal parameter set to the external memory
and has reset the start option to S
TART
WITH
EXTERNAL
P
ARAMETERS
)
CLX has loaded the internal parameter set.
•
Blinks constantly together with the "Read Result" LED
2)
(The external parameter memory is either not connected or corrupt, or the
parameter set is too large to be copied).
CLX has loaded the internal parameter set.
Read Result
Green
Start option: S
TART
WITH
EXTERNAL
P
ARAMETERS
(Default):
•
Blinks for approx. 10 s together with "Device Ready" LED
1)
(see above) or
•
Blinks constantly together with the "Device Ready" LED
2)
(see above)
Start option: S
TART
WITH
C
OPY
I
NTERN
-> E
XTERN
:
•
Blinks alternately with "Device Ready" LED for approx. 10 s (see above) or
•
Blinks constantly together with the "Device Ready" LED
2)
(see above)
Reading mode
Device Ready
Green
•
Lights up constantly
•
Extinguishes with new operating mode/function
Sensor
Green
•
Lights up if reading diode active.
(The laser diode is activated/deactivated by the reading pulse)
•
Lights up constantly in Free-running mode, since the laser diode is constantly
active
Read Result
Green
LED is linked to the "Result 2" output and indicates the selected result
status for the
defined pulse duration of the output.
•
Lights up after a successful read (default: Good Read)
•
Lights up if the match code comparison is active, the bar code read matches the
specified match code(s) and the corresponding result
output is selected for the
"Result 2" output
1) We recommend that you check the parameter set manually, e. g. by printing out the entire configuration. For troubleshooting, see also
Chapter 8.3.2 LED error messages
for the external parameter memory, Page 8-5
2) Stops blinking when you switch from Reading mode to Parameterization mode
Table 3-3: Meaning of LEDs: CLX with external parameter memory