Operation
6.5
Operating modes and outputing the reading result
The following CLX operating modes/functions can be selected in CLV-Setup:
Standard operating mode:
•
Reading mode
For setup:
•
Percentage evaluation
For adapting the device to the application at hand:
•
Configuring (parameterizing ) the CLX
Chapter 6.4.1 Configuring the CLX via the user interface of CLV-Setup, Page 6-5
•
Background teach-in
•
Background analysis
For monitoring purposes/troubleshooting
•
Display and edit operating data
•
Reading diagnosis
•
Monitor host interface
•
Auxiliary input
•
Self-test
6.5.1
Reading mode (standard operating mode)
The CLX performs a self-test after it has been switched on. It switches to Reading mode
("Device Ready" LED lights up). In the default setting the "Sensor" switching input is the (ex-
ternal) trigger source of the reading pulse. The reading result is output by the CLX at the end
of the reading pulse via the host interface (default setting) and terminal interface.
The reading result of the terminal interface can be displayed in the CLV-Setup Terminal
Emulator. The CLX terminal interface must be set to the R
EADING
D
IAGNOSIS
mode for this pur-
pose. This mode is selected for the default setting. The reading result of the terminal inter-
face has a fixed, invariable format.
The Reading mode can be called up by choosing V
IEW
in the menu bar or via the Terminal
Emulator.
Displaying the reading result in the Terminal Emulator:
1.
Click
in the toolbar.
The Terminal Emulator window is then displayed.
2.
In the D
EVICE
MODE
section, choose R
EADING
M
ODE
.
3.
Present the bar code pattern from
Fig. 6-1
to the CLX and activate the reading pulse.
The "Sensor" LED lights up and the scan line appears. Also refer to
ching the CLX on for the first time with the factory default settings, Page 6-3
4.
Ending the reading pulse.
The CLX displays the reading result in the output window of the terminal emulator.
The "Read Result" LED lights up for a duration of 100 ms (default setting).
shows two examples of the output of a reading result: Good Read and
No Read. The reading result comprises the data contents of the bar code(s) and the reading
explains the structure and function of the reading dia-
gnosis data for Good Read, and
for No Read.