Manual
PGT-09-S
44
SICK STEGMANN GmbH
Subject to change without notice
The Raw / Encoded bits selection is achieved by un-checking / checking the specific checkbox
in the panel placed on the left-top side where the corresponding total bits in the H-FRAME are
also shown. On the mid-right-top side the basic specification of the H-FRAME format (Raw /
Encoded) is shown as well.
Please note the bit enumeration: the 1
st
-transmitted bit is referred as bit47 (Raw) or bit59
(Encoded); hence the bit0 is the one transmitted last.
The following figure shows some more bit details:
Besides the selection above defining the fault target, a complete fault setup is also requiring the
fault specification, defined based on the selectors available in the specific panel, the following
one:
Starting from the left-end-side, the first drop-down
selector defines the “fault type” affecting the
range of the sequential bits (up to the whole frame), specified by means of both the next two
specific selectors (“From…To”). The total affected bits are also shown beside.
The selectable self-explained fault types are shown hereafter; the topmost selection (NONE)
can be simply used to make the fault configuration inactive.
A further specification is required; i.e., the quantity of the affected H-
FRAME’s; that can be
specified based on the selector placed on the right-end side.
Again, the topmost selection (NONE) can be used to make the fault configuration inactive.