NOTE
Assign the functions for the digital switching inputs in the device with a configuration
tool, e.g. the configuration software SOPAS ET.
14.5.8
Wiring digital switching inputs “External input 1” and “External input 2” of the device in the
CDB650-204
Device = RFU63x-131xx, RFU63x-041xx
Device = RFU65x-101xx
Device
4
CDB650-204
PNP sensor
7
V
S
GND
3.32 K
6.64 K
18 SGND
8
Shield
11 U
IN
*
A
Out
GND
S3
E.g. photo-electric
switch
6
Trigger sensor
1
CMC600
3
U
IN
*
Aux
(RS-232)
ON
OFF
S3 : SGND-GND
No
YES
S4 : CMC
V
in
“External
input
C
”
5
SensGND
EXT. IN
B
8
2
Figure 53: Trigger sensor supplied with power by connection module CDB650-204
1
Trigger sensor, e.g. for read cycle generation
2
Input voltage V
in
3
The optional parameter cloning module CMC600 is required in the connection module in order to be able to use the
additional external digital switching inputs and outputs of the device
4
Device
5
Logical “External input” in the device
6
e.g. photoelectric sensor
7
PNP sensor
8
Supply voltage V
S
ANNEX
14
8014335/ZTL9/2018-10-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | RFU63x, RFU65x
111