RD+/TD+
RD‒/TD‒
RD+/TD+
RD‒/TD‒
GND
Shield
4
Device
1
CDM420-0006
Host
5
.
.
.
TD+
TD‒
RD+
RD‒
GND
GND
GND
11
12
1
5
8
9
6
7
6
24
T+
34
T
‒
/TxD
25
R+
35
R
‒
/RxD
36
GND
6
Shield
RS-485
RS-485
ON
OFF
S2 : RS 485
ON
OFF
S3: Term 422
S2
ON
S3
OFF
120 Ω
-
RS-485 network:
3
2
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
1
10
15
6
11
5
6
5
Figure 61: Wiring data interface RS-485 of the device in the connection module CDM420-0006
1
Device
2
Adapter cable (male connector, D-Sub-HD, 15-pin / female connector, M12, 17-pin, A-coded)
3
RS-485 network
4
Shielding
5
Connection module: female connector, D-Sub-HD, 15-pin
6
Device: male connector, M12, 17-pin, A-coded
Function of switch S3
Table 54: Switch S3: Term 422
Switch setting
Function
ON
Terminates the device. Required if the device is located at the end of
the RS-485 bus cable.
OFF
No termination
NOTE
User of the RS-485 data interface:
•
The relevant interface drivers for the device comply with the standard in accor‐
dance with RS-422 and RS-485.
•
This operating mode is only permitted if all connected devices use a correspond‐
ing RS-485 protocol.
•
This configuration is not permitted when using the standard data output and pro‐
tocol of the device. In case of doubt, contact SICK Service.
•
Activate the RS-485 data interface (“Bus” option) in the device using a configura‐
tion tool, e.g. the SOPAS ET configuration software.
14.6.6
Wiring the CAN interface in the CDM420-0006
Device = RFU63x-131xx, RFU63x-041xx
Device = RFU65x-101xx
14
ANNEX
120
O P E R A T I N G I N S T R U C T I O N S | RFU63x, RFU65x
8014335/ZTL9/2018-10-14 | SICK
Subject to change without notice