1
2
3
6
3
5
4
4
7
Figure 13: Bracket made from tube elements and clamps in combination with a VESA adapter
plate, adjustment in 3 axes possible. Shown here mounted on the RFU630-131xx.
1
VESA adapter plate part no. 2071862 with 2 x M6 x 12 countersunk head screws, hexa‐
gon socket (WAF 4)
2
Hinged clamp part no. 2068919 with 4 x M6 x 12 cylinder head screws, hexagon socket
(WAF 5)
3
Tube, external diameter 30 mm, length 1 m, part no. 5327610
4
Sealing plug, external diameter 30 mm, part no. 5327613
5
Cross clamp, part no. 5327612
6
Base clamp, part no. 5327611
7
Base (e.g. plate, supplied by the user)
NOTE
Dimensional drawings for SICK brackets and, if applicable, mounting instructions can
be found online at:
b
To do so, enter the 7-digit part number of the bracket in the search field.
User-supplied brackets
A user-supplied bracket should meet the following requirements:
■
Stable mounting device
–
Allow the device to be aligned in the x and y axes.
–
The mounting device must be able to bear the weight of the device, including
connecting cables, in a shock-proof manner,
–
In mounting situations with strong vibrations, it may be necessary to provide
shock mounts.
MOUNTING
5
8014335/ZTL9/2018-10-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | RFU63x, RFU65x
35
Subject to change without notice