8
Adapter cable (male connector, M12, 4-pin, D-coded/male connector, RJ-45, 8-pin)
9
For CDB650-204: Connection cable 1:1 (female connector, M12, 17-pin, A-coded/male
connector, M12, 17-pin, A-coded)
For CDM420-0006: Adapter cable (female connector, M12, 17-pin, A-coded/male con‐
nector, D-Sub-HD, 15-pin)
ß
Cable (male connector, TNC reverse/male connector, TNC reverse)
à
External antennas (optional), e.g. RFA630-000
8)
Read operation
In real operation, the device outputs the read result to the processing computer via one
of the two physical host interfaces. One of two configurable output formats can be
selected for this purpose. The device can also output the same or the second output
format via the second host interface and/or both Aux interfaces at the same time.
For a detailed overview,
see "Use of the data interfaces", page 51
.
...
...
1 2
V
S
GND
...
1
4
RFU63x-
041xx
External antennas
7
Input 2
3
Input 1
4
Output 1
2
Output 2
1
V
S
"Serial RS-232/RS-422/485" (Host 1)
à
"Ethernet“ (Host 2)"
Cable
á
"Power/Serial Data/CAN/I/O"
(Aux 1, Host 1)
Cable
9
Cable
â
Reading result
8
HOST
Further data
processing
Ethernet
Ethernet
ß
5
6
Connection
module
Figure 23: Read operation: RFU63x-041xx with optional connection module
1
Digital switching output 2, for example for connecting an LED
2
Digital switching output 1, for example for connecting an LED
3
Digital switching input 2, for example for connecting an incremental encoder
4
Digital switching input 1, e.g. for connecting a read cycle trigger sensor
5
Supply voltage V
S
(V
S
= U
V
)
6
Connection module CDB650-204 or CDM420-0006
7
External antennas (optional), e.g. RFA630-000
8)
8
Read result (configurable output format 1 or 2)
9
Data further processing
ß
Adapter cable (male connector, M12, 4-pin, D-coded/male connector, RJ-45, 8-pin)
à
Alternative to Ethernet host port
á
For CDB650-204: Connection cable 1:1 (female connector, M12, 17-pin, A-coded/male
connector, M12, 17-pin, A-coded)
For CDM420-0006: Adapter cable (female connector, M12, 17-pin, A-coded/male con‐
nector, D-Sub-HD, 15-pin)
â
Cable (male connector, TNC reverse/male connector, TNC reverse)
8)
For regional assignment, see online data sheet at:
6
ELECTRICAL INSTALLATION
48
O P E R A T I N G I N S T R U C T I O N S | RFU63x, RFU65x
8014335/ZTL9/2018-10-14 | SICK
Subject to change without notice