NOTE
As an option, two additional external digital switching inputs and output are available
for the device. Parameter cloning module CMC600, installed in the CDB or CDM con‐
nection module, is required for this purpose.
The modules can be delivered as optional accessories.
For the properties of the external digital switching inputs and outputs
digital switching inputs ", page 67
see "Wiring the digital switching outputs ",
.
6.3.3
RFU65x-101xx with internal antenna
Service operation
The following functions in the device, among others, can be performed by the user
using one of five data interfaces (Aux 1, Aux 2, Aux 3, Host 1 or Host 2):
•
Configuration
•
Representation of the reading result (detected transponders)
•
Transponder access (reading and writing data)
•
Reading diagnostics (read result in fixed output format)
For a detailed overview,
see "Use of the data interfaces", page 51
.
Shown here for the Aux interface is the Aux port of the Ethernet interface and, as alter‐
natives, the serial data interface and the USB interface. The USB interface is only for
temporary use as a service interface.
Cable
9
Serial
Serial
Cable
8
Cable
6
SOPAS ET
SOPAS ET
"Power/Serial Data/CAN/I/O"
(Aux 1, Host 1)
...
...
1 2
V
S
GND
PC
Cable
3
"Serial RS-232" (Aux 1)
4
"Ethernet" (Aux 2)
V
S
USB
USB
Ready
Result
RF
Data
CAN
LNK TX
microSD
TeachIn
Antenna
Sync
Userdef.
Read Diagn
RFU65x-101xx
1
2
Connection
module
Ethernet
Ethernet
7
"USB" (Aux 3),
for temporary use only
5
Configuration
Reading result
display
Transponder
access
Reading
diagnostics
Figure 24: Service operation, e.g. representation of the read result: RFU65x-101xx block diagram
with optional connection module
1
Supply voltage V
S
(V
S
= U
V
)
2
Connection module CDB650-204 or CDM420-0006
3
Null modem cable (female connector, D-Sub, 9-pin/female connector, D-Sub, 9-pin),
crossed TxD and RxD
4
Serial RS-232, alternative to USB or Ethernet Aux port
5
USB, alternative to serial RS-232 or Ethernet Aux port
6
Adapter cable (male connector, USB, Micro-B type / male connector, USB, type A)
7
Configuration with SOPAS ET, prepared representation of the read result, transponder
access or reading diagnostics
8
Adapter cable (male connector, M12, 4-pin, D-coded/male connector, RJ-45, 8-pin)
9
For CDB650-204: Connection cable 1:1 (female connector, M12, 17-pin, A-coded/male
connector, M12, 17-pin, A-coded)
ELECTRICAL INSTALLATION
6
8014335/ZTL9/2018-10-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | RFU63x, RFU65x
49
Subject to change without notice