6.6
Installation steps
6.6.1
Wiring of the device for Quickstart
RFU63x-131xx (with internal antenna)
Cable
7
Cable
8
Cable
6
SOPAS ET
SOPAS ET
"Power/Serial Data/CAN/I/O"
(Aux 1, Host 1)
...
...
1 2
V
S
GND
PC
"Ethernet" (Aux 2)
External antennas
4
...
1
3
Ethernet
Ethernet
RFU63x-
131xx
5
11 10 12
Trigger
sensor
SGND
Sens 1
V
S
1
Out
GND
V
S
2
3
Connection
module
Configuration
Reading result
display
Transponder
access
Reading
diagnostics
Figure 30: Commissioning: Electrical connection block diagram of the RFU630-131 xx with
optional connection module
1
Reading pulse trigger
2
Supply voltage V
S
3
CDB650-204 or CDM420-0006 connection module
4
External antennas (optional), e.g. RFA630-000 for Europe/Saudi Arabia/South Africa
region
5
Configuration or diagnostics
6
Adapter cable (male connector, M12, 4-pin, D-coded / male connector, RJ-45, 8-pin)
7
For CDB650-204: Connection cable 1:1 (female connector, M12, 17-pin, A-coded / male
connector, M12, 17-pin, A-coded)
For CDM420-0006: Adapter cable (female connector, M12, 17-pin, A-coded / male con‐
nector, D-Sub-HD, 15-pin)
8
Cable (female connector TNC / female connector, TNC)
1
Trigger sensor for read cycle
2
Supply voltage V
S
(V
S
= U
V
)
3
Connection module CDB650-204 or CDM420-0006
4
External antennas (optional), e.g. RFA630-000
9)
5
Configuration with SOPAS ET, prepared representation of the read result, transponder
access or reading diagnostics
6
Adapter cable (male connector, M12, 4-pin, D-coded/male connector, RJ-45, 8-pin)
7
For CDB650-204: Connection cable 1:1 (female connector, M12, 17-pin, A-coded/male
connector, M12, 17-pin, A-coded)
For CDM420-0006: Adapter cable (female connector, M12, 17-pin, A-coded / male con‐
nector, D-Sub-HD, 15-pin)
8
Cable (male connector, TNC reverse/male connector, TNC reverse)
Procedure:
1.
Connect the communication interface (e.g., Ethernet) of the device directly to the
PC using the suitable cable
6
.
2.
If additional external antennas are used (maximum 3, e.g., RFA630-000), these
must be connected to the antenna inputs of the device by means of suitable con‐
necting cables
8
.
9)
For regional assignment, see online data sheet at:
ELECTRICAL INSTALLATION
6
8014335/ZTL9/2018-10-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | RFU63x, RFU65x
55