Wiring with SICK connection module
Deliver the supply voltage via a connection module:
Connection module
Interface
Reference
CDB650-204
Supply voltage
see "Connecting supply voltage
for the device in CDB650-204",
page 104
CDM420-0006
Supply voltage
see "Connecting supply voltage
for the device in
CDM420-0006", page 117
6.9
Wiring data interfaces
Wiring the Internet interface
1.
Connect the device to the Ethernet interface of the PC via an adapter cable.
2.
Set up communication via SOPAS ET configuration software.
NOTE
The Ethernet interface of the device has an Auto-MDIX function. This automatically
adjusts the transmission speed as well as any necessary crossover connections.
Wiring the serial data interfaces
The maximum data transmission rate for the serial interface depends on the length of
cable and on the type of interface. Observe the following recommendations:
Table 14: Serial interfaces: data transmission rates
Interface
Data transmission rate
Distance to the target computer
(host)
RS-232
Up to 19.2 kBd
38.4 kBd ... 57.6 kBd
115.2 kBd … 500 kBd
Max. 10 m
Max. 5 m
< 2 m
RS-422/485
1)
Up to 38.4 kBd
38.4 kBd ... 57.6 kBd
57.6 kBd … 500 kBd
Max. 1,200 m
Max. 500 m
Max. 10 m
1)
For RS-422/485-suitable cable and corresponding cable termination as per specification.
NOTICE
Risk of damage to the internal interface modules!
If the serial data interfaces are wired incorrectly, then electronic components in the
device could get damaged.
■
Observe the information on wiring.
■
Carefully check the wiring prior to switching on the device.
ELECTRICAL INSTALLATION
6
8014335/ZTL9/2018-10-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | RFU63x, RFU65x
65
Subject to change without notice