RFU63x-131xx
Dimensions (L x W x H)
239 mm x 239 mm x 64 mm
6)
1)
When connected to the optional SICK CDB650-204 or CDM420-0006 connection module using a SICK
cable.
2)
When operated without a connection module using a SICK cable. 2 A fuse protection at the start of the
feeding supply circuit.
3)
When operated without a connection module using a SICK supply cable part no. 6048319 (2 x 2.5 mm
2
,
10 m). 2.5 A fuse protection at the start of the feeding supply circuit.
4)
At full transmitting power and unloaded switching outputs.
5)
With a typical loading of the 2 switching outputs of 100 mA each and a 30 V DC supply voltage.
6)
Table 27: Technical data for RFU63x-041xx: Mechanics/electronics
RFU63x-041xx
Electrical connection
1 x male connector, M12, 17-pin, A-coded
1 x female connector, M12, 4-pin, D-coded
1 x female connector, USB, 5-pin, Micro-B type
4 x female connector, TNC reverse, mono-static, impedance
50 ohm
Supply voltage V
S
DC 18 V ... 30 V
1)
2)
DC 12 ... 30 V
3)
optional
SELV in accordance with currently applicable standard EN
60950-1.
UL-certified devices require a supply voltage in accordance with
SELV - LPS according to UL/IEC/EN60950-1 or class 2 according
to NEC, UL1310.
Power consumption
temperature:
•
< 20 W typical
4)
•
Maximal 26 W
5)
Standby: 6 W typical
Housing
Aluminum die cast, polycarbonate
Housing color
Blue, black, silver
Cover for USB interface
Aluminum Can be removed for temporary access to USB interface
and memory card slot. Recommended tightening torque for the
cover screws: 40 Ncm ± 5 Nm.
Enclosure rating
IP67 (EN 60529:1991-10/A2:2000-02)
Protection class
III (EN 61140:2006-08)
Safety
EN 60950-1:2006-04/A11: 2009-03/A1: 2010-03/A12: 2011-02
Weight
Approx. 2.1 kg
Dimensions (L x W x H)
239 mm x 197 mm x 40 mm
6)
1)
When connected to the optional SICK CDB650-204 or CDM420-0006 connection module using a SICK
cable.
2)
When operated without a connection module using a SICK cable. 2 A fuse protection at the start of the
feeding supply circuit.
3)
When operated without a connection module using a SICK supply cable part no. 6048319 (2 x 2.5 mm
2
,
10 m). 2.5 A fuse protection at the start of the feeding supply circuit.
4)
At full transmitting power and unloaded switching outputs.
5)
With a typical loading of the 2 switching outputs of 100 mA each and a 30 V DC supply voltage.
6)
12.1.4
Ambient data
Table 28: Technical data for RFU63x-131xx: Ambient data
RFU63x-131xx
Electromagnetic compati‐
bility (EMC)
EN 301489-3
12
TECHNICAL DATA
92
O P E R A T I N G I N S T R U C T I O N S | RFU63x, RFU65x
8014335/ZTL9/2018-10-14 | SICK
Subject to change without notice