RFU65x-101xx
Antenna
Internal antenna
•
Transmitting power adjustable
•
Circularly polarized
•
Axis behavior typically 2 dB
•
Aperture angle vertical 80° / horizontal 55°
•
Front-to-back ratio, > 15 dB typical
Service functions
Optional, automated saving of parameter data (parameter cloning)
outside the device memory:
•
Using insertable microSD memory card
3)
in the device
•
Using parameter cloning module CMC600
3)
in the CDB
3)
or
CDM
connection module
3)
•
Externally in CDF
fieldbus module
3)
Clock
Network time protocol (NTP), no internal clock
Conformities
Type-dependent. See type-specific online data sheet at:
Certificates
Type-dependent. See “Downloads” section online at:
UL: RFU650-10101 (USA and Canada)
4)
1)
Continuous operation at an ambient operating temperature of +50 °C.
2)
Depending on transponder used and ambient conditions
3)
Optional accessories.
4)
UL-certified if the type label contains the UL logo and the UL conditions are met during device operation.
For further information,
see "Certification according to UL61010-1", page 98
.
12.2.2
Interfaces
Table 31: Technical data for RFU65x: Interfaces
RFU65x-101xx
Ethernet
Host for data output (read result)
Aux for service
1)
Protocol: TCP/IP
Data transmission rate 10/100 Mbit/s
Supported services and protocols (e.g. DHCP, HTTP/HTTPS ...), see
type-specific online data sheet at:
PROFINET
2)
PROFINET single port
PROFINET dual port: Via external fieldbus module CDF600-22xx
4)
to PROFINET (2-port Ethernet) for data output (read result)
Data transmission rate 10/100 Mbit/s
EtherNet/IP
™
Data transmission rate 10/100 Mbit/s
EtherCAT
®
2)
Via external fieldbus module CDF600-0300
4)
(gateway mode) to
EtherCAT® (Ethernet) for data output (read result)
Serial
RS-232, RS-422/485
Host for data output (read result)
Aux (only RS-232) for service
1)
Data transmission rate: 0.3 kBd ... 115.2 kBd, Aux: 57.6 kBd
CAN
Host, data transmission rate: 20 kBit/s ... 1 MBit/s.
Bus length depends on data transmission rate and length of
cable. Typical: 250 m at 250 kBit/s and wire cross-section
≥
0.34
mm
2
Protocols:
•
CSN (SICK CAN sensor network)
•
CANopen
®
12
TECHNICAL DATA
94
O P E R A T I N G I N S T R U C T I O N S | RFU63x, RFU65x
8014335/ZTL9/2018-10-14 | SICK
Subject to change without notice