A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
R F U 6 3 x – I n t e R R o g at o R s ( W R I t e / R e a d U n I t s ) | s I c K
8014330/2012-12-19
Subject to change without notice
Interrogators (write / read units)
6
RFU63x
Interfaces
compact device with integrated antenna
(write/read unit)
Interrogator
(write/read unit)
serial (Rs-232, Rs-422/485)
l
Function Host, AUX
Data transmission rate 300 Baud ... 115.2 kBaud, AUX: 57.6 kBaud (RS-232)
UsB
l
, USB 2.0
Function AUX
ethernet
l
Function Host, AUX
Data transmission rate 10/100 Mbit
Protocol TCP/IP, EtherNet/IP, PROFINET
can bus
l
Function Host
Protocol CSN (SICK CAN Sensor Network)
PRoFIBUs dP
l
, optional via external connection module (CDF)
switching inputs
4 (“Sensor 1”, “Sensor 2”, 2 inputs via optional CMC600 in CDB620/CDM420)
switching outputs
4 (“Result 1”, “Result 2”, 2 outputs via optional CMC600 in CDB620/CDM420)
optical indicators
8 LED, one of them multi-colored (function configurable via SOPAS, alternatively controlling with
sw commands, status displays)
acoustic indicators
1 beeper/buzzer (can be switched off, can be allocated as a result status indication function)
control elements
2 buttons (choose and start/stop functions)
Mechanics/electronics
electrical connection
1 x M12, 17-pin plug
1 x M12, 4-pin socket Ethernet
Cylindrical connectors
operating voltage
12 V DC ... 30 V DC
1)
Power consumption
< 20 W, with switching outputs not connected and full transmit power
Housing
Die-cast aluminum
enclosure rating
IP 67
Protection class
III
Weight
3.5 kg
dimensions
239 mm x 239 mm x 64 mm
1)
Limited operating voltage range in combination with CDB620 and CDF600.
Ambient data
Electromagnetic compatibility (EMC)
EN 61000-6-3 (2001-10) / EN 61000-6-2 (2009-05)
Vibration resistance
EN 60068-2-6 (2008-02)
shock resistance
EN 60068-2-27 (2009-05)
ambient operating temperature
–25 °C ... +50 °C
storage temperature
–30 °C ... +70 °C
Permissible relative humidity
± 90 %, non-condensing