background image

A

B

C

D

E
F

G
H

I

J

K

L

M

N
O

P

Q
R

©

 SICK, Inc., USA. All rights, including changes to technical specifications 

and or to the equipment without prior notification, are reserved.

C - 57

S300 Standard 

Safety laser scanner

7024240

■ 

Extremely compact design

■ 

Scanning angle 270°

■ 

Selectable resolution

■ 

Certified for vertical and 

horizontal use

■ 

7-segment display

■ 

Integrated external device 

monitoring (EDM)

■ 

Stand-by input

IEC 61508

Compliant

Further information

Page

➜ 

Ordering information

C-58

➜ 

Technical specifications C-58

➜ 

Dimensional drawings C-59

➜ 

Connection diagrams C-61

➜ 

Accessories

C-62

➜ 

Services

A-2

Overview of technical specifications

Protective field range

2 m

Warning field range

8 m (at 30 % reflectivity)

Number of field sets

1

Scan angle

270°

Resolution

30 mm, 40 mm, 50 mm, 70 mm, 
selectable

Response time

80 ms

Type

Type 3 (IEC/EN 61496-3)

Safety integrity level

SIL2 (IEC/EN 61508)

Product description

High-end safety at entry level price
The low-cost solution for simple require-

ments with one protective field and war-

ning field.
Ideal for the horizontal and vertical protec-

tion of hazardous areas and areas of 

access.

With adjustable object resolution as well as 

configurable "contour as reference."

■ 

1 protective and warning field

■ 

New multi-system "Configuration & Diag-

nostic Software" CDS

In-system added value

■ 

Supports integration with multiple safety control solutions

➜ 

For safety system combinations, see appendix "Sensor systems and safe control solutions 

 

from SICK"

■ 

Freely moving transport vehicles

■ 

Production lines

■ 

Machining centres

■ 

Entry/Exit stations

■ 

Robot cells

■ 

Overhead monorail transport systems

Hazardous area protection on an AGV with one 
direction of travel

Hazardous area protection on a robot cell

Applications

➜ 

You can find more applications using the application finder at www.sickusa.com/applications

WS/WE 12-2

Summary of Contents for S300 Standard

Page 1: ...pe 3 IEC EN 61496 3 Safety integrity level SIL2 IEC EN 61508 Product description High end safety at entry level price The low cost solution for simple require ments with one protective field and war n...

Page 2: ...IEC EN 61496 3 Safety integrity level SIL2 IEC EN 61508 Ambient operating temperature from to 10 C 50 C Type of light Pulsed laser diode Wave length 905 nm Housing colour RAL 1021 Housing material Alu...

Page 3: ...oltage Vs 24 V DC 16 8 V DC 30 V DC Power consumption 0 33 A 24 V DC Power consumption 1 65 A 1 Number of inputs EDM Restart Reset Standby 1 1 1 Number of safety capable outputs Safety outputs OSSD Ou...

Page 4: ...ing changes to technical specifications and or to the equipment without prior notification are reserved C 60 S300 Standard Safety laser scanner 7024240 Scan plane origin 73 130 146 270 23 8 116 36 4 7...

Page 5: ...ntactors Operating mode with restart interlock and external device monitoring EDM Comments 1 Output circuits These contacts are to be connected to the controller such that with the output circuit open...

Page 6: ...can be easily identified via the comprehensive diagnostics functions That significantly reduces machine down times SICK offers solutions for the open automation standards AS i Safety at Work DeviceNe...

Page 7: ...necting the configuration connection to the PC M8 x 4 SUB D 9 pol 2 m 6021195 8 m 2027649 Configuration software Type Description Part number CDS CDS Configuration Diagnostic Software on CD ROM includ...

Page 8: ...hanges to technical specifications and or to the equipment without prior notification are reserved C 64 S300 Standard Safety laser scanner 7024240 Mounting kit 2 31 7 33 4 18 19 7 19 7 18 4 78 2 40 7...