Field set comprising a protective field and warning field(s)
Protective fields and warning fields form the so-called field set. These field sets are con‐
figured using the CDS. You can configure the fields to be radial, rectangular or free
form. When the area to be monitored changes, you can reconfigure the safety laser
scanner via the software without additional mounting work.
You can configure different field sets:
•
Field sets that comprise one protective field and one warning field
•
Field sets that comprise two protective fields
•
Field sets that comprise one protective field and two warning fields
1
2
3
Figure 6: Triple field mode with one protective field and two warning fields
1
2
3
3.2.5
Monitoring cases
For stand-alone operation, four monitoring cases can be programmed. Up to 32 moni‐
toring cases can be defined and selected during operation via EFI. This makes it possi‐
ble, for example, to perform process-dependent hazardous area protection or speed-
dependent vehicle monitoring.