Figure 73: Configuration example for the universal I/O connections of the S3000
NOTE
If you operate the device in the compatibility mode, then the connections on the univer‐
sal I/O are used as an application diagnostic output, warning field output, and applica‐
tion diagnostic output for Reset required.
7.11.1
Application diagnostic output in the compatibility mode
The device has a configurable application diagnostic output in the compatibility mode.
You can configure the following for the application diagnostic output in the CDS:
•
Whether the application diagnostic output is deactivated.
•
Whether a signal is only output when the front screen is contaminated.
•
Whether a signal is only output on errors.
•
Whether a signal is output both for front screen contamination and on errors.
7.12
Field Sets
The number of field sets that can be configured depends on the safety laser scanner
variant.
On the S3000 Expert and S3000 Remote, the number of field sets that can be config‐
ured also depends on the field mode selected (dual field mode/dual protective field
mode/ triple field mode) and the angular resolution configured. The following table
shows the number of field sets per variant and application:
Table 22: Number of field sets that can be configured per use
Angular resolution
Standard
Advanced
Professional
Expert
Remote
Dual field mode/dual
protective field mode
Configured angular
resolution 0.5°
1
4
8
32
32
Configured angular
resolution 0.25°
1
4
8
16
16
Triple field mode
7
CONFIGURATION
100
O P E R A T I N G I N S T R U C T I O N S | S3000