10)
Make sure to limit the individual conductor resistances to the downstream controller to this value to
ensure that a cross-circuit between the outputs is safely detected. (Also note EN 60204-1.)
11)
When active, the outputs are tested cyclically (brief LOW). When selecting the downstream controllers,
make sure that the test pulses do not result in deactivation.
12.2
Characteristic curves
Scanning range for warning fields
1
2
5
10
20
50
100
200
500
0,1
0,2
0,5
1
2
5
10
20
50
1
2
3
4
5
6
R [%]
D [m]
Figure 88: Diagram scanning range with Short Range sensor head
R
Necessary minimum radiance factor in %
D
Scanning range in m
1
Black shoe leather
2
Matt black paint
3
Gray cardboard
4
Writing paper
5
White plaster
6
Reflectors > 2,000%, reflective tapes > 300%