The safety laser scanner must be arranged and configured in such a manner that
it can detect objects entering into the hazardous area.
•
The optical path of the safety laser scanner must be kept clear at all times and
must also not be obscured by transparent objects such as protective screens, plex‐
iglass, lenses, etc. The protective function of the safety laser scanner can only be
guaranteed if the contamination measurement function is not circumvented by
such measures.
Further topics
•
•
3.2
Product characteristics
3.2.1
Specific features
•
190° scanning angle
•
Increased dust and particle tolerance due to dazzle and particle algorithms
•
Sensor heads with a scanning range up to 4 m, 5.5 m or 7 m (maximum radii of
the protective field)
•
Various I/O modules for different fields of applications
•
Easy exchange of the I/O module. This makes it easy to extend the functionality.
•
Configuration via PC or notebook using the SICK Configuration & Diagnostic soft‐
ware
•
Configuration memory in the system plug. If the device is exchanged, the existing
configuration is automatically transmitted to the newly-connected safety laser
scanner. This considerably reduces downtimes.
•
Dual field mode with field sets comprising a protective field and a warning field
(optional simultaneous monitoring of 2 field sets)
•
Dual protective field mode with field sets comprising 2 protective fields (optional
simultaneous monitoring of 2 field sets = 4 protective fields)
•
Triple field mode with field sets comprising one protective field and 2 warning
fields
•
Contour monitoring of a protective field
•
•
Integrated external device monitoring (EDM)
•
Integrated configurable restart interlock/restart delay
•
Secure bus connection via Enhanced Function Interface (EFI) for operation in a
system network with other safety laser scanners, with products in the sens:Control
product group, or with a Flexi Soft safety controller
•
Compatibility mode for interoperability with older generation safety laser scanners
S3000 Advanced or higher
•
Up to 4 field sets
•
Monitoring case switching via static inputs or EFI
S3000 Professional or higher
•
Up to 8 field sets
•
Monitoring case switching via dynamic inputs using incremental encoder
•
Speed routing using a Flexi Soft safety controller
S3000 Expert and Remote
1)
•
Up to 32 field sets (in dual field mode or dual protective field mode)
•
Up to 21 field sets (in triple field mode)
S3000 Expert
•
CMS feature for detecting reflectors as artificial landmarks
1)
Sensor head with firmware ≥ B02.41 and I/O module with serial number > 11240000.
PRODUCT DESCRIPTION
3
8009942/ZA18/2019-11-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | S3000
15
Subject to change without notice