Monitoring case switching between an S3000 Expert and an S300 Mini Remote using
static and dynamic inputs
2
3
4
5
6
7
H
1
H = Housing
FE
0 V
S300 Mini Remote
5
10
16
12
18
23
14
21
7
3
9
1
6
13
11
17
15
19
22
20
4
2
8
k2
k1
1)
x
x
y
y
z
z
k2
k1
K1
K2
H8
H2
IN A1
A2
k1
k2
IN B1
B2
+24 V
BN
GN
YE
PK
BU
FE
WH
GY
S3000
Expert
E113000/01/2015-03-25
90°
0°
–
+
1/f
HTL
90°
0°
–
+
1/f
HTL
Figure 53: Connection diagram for monitoring case switching between an S3000 Expert and an
S300 Mini Remote using static and dynamic inputs
S3000 Expert and S300 Mini Remote in an EFI system in conjunction with relays (con‐
tactors); Operating mode: without restart interlock, with external device monitoring; Sta‐
tic monitoring case switching by the control inputs A and B of the S3000; Direction of
travel-dependent dynamic monitoring case switching by the incremental encoders C
and D of the S3000. The protective fields act on the OSSDs on the S3000.
Monitoring case switching between an S3000 and an S300 using static and dynamic
inputs
+24 V
0 V
FE
S3000 Professional
S300 Professional
Figure 54: Connection diagram for monitoring case switching between an S3000 and an S300
using static and dynamic inputs
4
PROJECT PLANNING
62
O P E R A T I N G I N S T R U C T I O N S | S3000
8009942/ZA18/2019-11-14 | SICK
Subject to change without notice