S3000 Professional and S300 Professional in an EFI system in conjunction with relays
(contactors); Operating mode: without restart interlock, with external device monitoring;
Static monitoring case switching by the control inputs A and B of the S3000; Direction
of travel-dependent dynamic monitoring case switching by the incremental encoders C
and D of the S3000. The protective fields act on the OSSDs on the S3000.
Monitoring case switching between S3000 and S300 using a Flexi Soft safety con‐
troller
S300 Professional
S3000 Professional
FX3-XTIO
FX3-CPU1
UE10-2FG
+24 V
FE
0 V
Figure 55: Connection diagram for monitoring case switching between S3000 and S300 usin a
Flexi Soft safety controller
S3000 Professional and S300 Professional in an EFI system; Protective field evalua‐
tion, restart interlock and EDM via EFI using a Flexi Soft safety controller; Static moni‐
toring case switching via EFI by the control inputs S1 to S4 of the Flexi Soft safety con‐
troller.
PROJECT PLANNING
4
8009942/ZA18/2019-11-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | S3000
63
Subject to change without notice