A1
A2
B1
B2
Result (e.g., monitoring case no.)
0
0
1
0
3
0
0
0
1
4
0
0
0
0
Error
1
1
0
0
Error
NOTE
•
All connections must be connected.
•
Only one connection is ever allowed to be 1.
Further topics
•
"Monitoring case switching via static input information", page 106
7.9
OSSDs
In an EFI system, you define in the CDS which output signal switching device (OSSD) is
switched when there is an object in the protective field.
•
Internal OSSDs
Defines that the protective field 1 and/or the simultaneous protective field 1
switches the internal OSSDs on the safety laser scanner.
DANGER
No switching of the OSSDs by the protective field 2 and the simultaneous protec‐
tive field 2
The dangerous state may not be stopped in the event of non-compliance.
If you have selected the
Dual protective fields
field mode, then protective field 2 and
the simultaneous protective field 2 do not switch the OSSDs.
b
You must therefore route the cut-off signals for protective field 2 and simulta‐
neous protective field 2 via the EFI interface to the external OSSDs on a Flexi
Soft safety controller.
•
External OSSDs
The device transmits the status of the field sets (protective field/warning fields) via
the EFI interface. The OSSDs on another device connected via the EFI interface
are switched.
°
Connected S300 or S3000: The OSSDs on the second safety laser scanner
are switched.
°
Connected safety controller (e.g., Flexi Soft): The OSSDs on the safety con‐
troller are switched depending on its configuration.
°
Connected network solution (e.g., safety remote I/O): The information is
passed via the network e.g., to an FPLC that must shutdown the dangerous
state.
DANGER
Incorrect use of the OSSD bit
The dangerous state may not be stopped in the event of non-compliance.
If the local OSSDs on the device are not used, the OSSD state is always transferred as
active via EFI. In this case, the OSSD bit in the Flexi Soft safety controller must not be
used for safety-related functions.
b
Do not use the OSSD bit for safety-related functions.
Use the status information from the protective fields instead.