Further topics
•
4.3.2
Measures to prevent unsecured areas
Overview
When mounting the safety laser scanner, there may be areas which it cannot detect
(
1
).
1
X
X
Y
Y
Figure 26: Unsecured areas in stationary applications
1
X
Figure 27: Unsecured areas in mobile applications
These areas become larger if you mount the safety laser scanner using the mounting
kits.
Table 5: Size of the unsecured areas
Installation variant
Size of the unsecured areas
X
Y
Direct mounting
109 mm
1,245 mm
Using mounting kit 1
112 mm
1,280 mm
Using mounting kits 1 and 2
127 mm
1,452 mm
Using mounting kits 1, 2 and 3
142 mm
1,623 mm
4
PROJECT PLANNING
36
O P E R A T I N G I N S T R U C T I O N S | S3000
8009942/ZA18/2019-11-14 | SICK
Subject to change without notice