2
Figure 58: Mounting using mounting kit 1
1
Mounting kit 1
2
Fixing screws
3
Threaded mounting holes M8×9
Approach
1.
Mount kit 1 on the mounting surface.
2.
Mount the safety laser scanner on mounting kit 1.
NOTE
Observe the maximum permissible tightening torque of 16 Nm for the M8 × 9
threaded mounting holes.
5.2.3
Mounting using mounting kit 2
Overview
You can use mounting kit 2 (only in conjunction with mounting kit 1) to align the device
in 2 planes. The maximum adjustment angle is ± 11° in both planes.