1
2
5
10
20
50
100
200
500
0,1
0,2
0,5
1
2
5
10
20
50
1
2
3
4
5
6
R [%]
D [m]
Figure 75: Diagram scanning range with Long Range sensor head
R
Necessary minimum radiance factor in %
D
Scanning range in m
1
Black shoe leather
2
Matt black paint
3
Gray cardboard
4
Writing paper
5
White plaster
6
Reflectors > 2,000%, reflective tapes > 300%
If the reset pulse on the “Reset” input is, for example, provided by an (F)PLC, then the
pulse must be of a specific length.
≥ 500 ms
0
10
20
24
U [V]
t [ms]
Figure 76: Reset pulse requirements
Make sure that pulses do not have a frequency of 1 Hz or 4 Hz, as otherwise there may
be overlaps with the output signals for “Front screen contaminated” or “System error”.
This overlap will result in an error on the safety laser scanner.
TECHNICAL DATA
12
8013291/ZA19/2019-11-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | S3000 PROFINET IO, S3000 PROFINET IO-OF
119
Subject to change without notice