Important information
DANGER
In the case of non-compliance, it is possible that the dangerous state of the machine
may not be stopped or not stopped in a timely manner.
The minimum distance to the hazardous area depends on the monitoring situation.
b
Make sure that the minimum distance to the hazardous area is maintained for
each monitoring case.
Configurable monitoring cases
The number of monitoring cases that can be configured depends on the variant and the
control. The following table shows the number of monitoring cases:
Table 14: Number of monitoring cases
Advanced
Professional
4
16
Complementary information
You can configure the monitoring cases in the CDS.
Each monitoring case includes the following information:
•
The input conditions, the so-called control signals that control the activation of the
monitoring case.
•
A field set comprising a protective field and warning field(s).
•
If necessary, a simultaneous field set.
•
If necessary, a unique follow-on case or two alternative follow-on cases.
•
The multiple sampling for the field set.
•
The multiple sampling for the simultaneous field set.
Monitoring cases can be switched with static input information.
Further topics
•
7.11.1
Monitoring case switching via static input information
Overview
For monitoring case switching via static input information, you configure for each moni‐
toring case the input condition to be used to switch to this monitoring case.
Important information
WARNING
Persons or parts of the body to be protected may not be recognized or not recognized in
time in case of non-observance.
Someone may already be in the protective field at the time of switchover. Only by switch‐
ing in the correct time frame, i.e., before the hazard occurs at this point for the person,
is protection provided (
see "Timing for monitoring case switching", page 34
b
Make sure that the control – using static control inputs – provides switching
between the monitoring cases in the correct time frame.
7
CONFIGURATION
84
O P E R A T I N G I N S T R U C T I O N S | S3000 PROFINET IO, S3000 PROFINET IO-OF
8013291/ZA19/2019-11-14 | SICK