12
Technical data
12.1
Process image S3000 PROFINET IO/IO-OF Advanced
The process contains data on four monitoring cases and four field sets.
INPUT
Table 23: Process image S3000 PROFINET IO/IO-OF Advanced INPUT
Bit
Description
Byte 0 0.0
0.1
Warning field clear
0.2
Simultaneous protective field clear
0.3
Simultaneous warning field clear
0.4
Reset required (protective field)
0.5
Reserved
0.6
Reset required (simultaneous protective field)
0.7
Reserved
Byte 1 1.0
Contamination
1.1
1.2
Monitoring case number – Bit 0
1.3
Monitoring case number – Bit 1
1.4
Reserved
1.5
Reserved
1.6
Reserved
1.7
Reserved
Byte 2 2.0
Reserved
2.1
Reserved
2.2
Reserved
2.3
Reserved
2.4
Reserved
2.5
Reserved
2.6
Reserved
2.7
Reserved
Byte 3 3.0
Reserved
3.1
Reserved
3.2
Reserved
3.3
Reserved
3.4
Reserved
3.5
Reserved
3.6
Reserved
3.7
Reserved
12
TECHNICAL DATA
106
O P E R A T I N G I N S T R U C T I O N S | S3000 PROFINET IO, S3000 PROFINET IO-OF