Bit
Description
Byte 5 5.0
Reserved
5.1
Reserved
5.2
Reserved
5.3
Reserved
5.4
Reserved
5.5
Reserved
5.6
Reserved
5.7
Reserved
12.3
PROFINET diagnostic messages
Operational statuses:
•
Waiting for configuration
•
Lock-out
•
Device error
•
Error in the sensor head
•
Error in the I/O module
•
Error in the system plug
•
Measured value error in a 90° segment
•
Dazzle
•
Temperature error
•
Undefined monitoring case
•
Sequence error in field set switching
•
Invalid input state
•
Contamination error or contamination measurement
•
PROFIsafe communication error
12.4
Data sheet
General details
Table 27: General details
Minimum
Typical
Maximum
Type
Type 3 (IEC 61496-1)
Safety Integrity Level
1)
SIL2 (IEC 61508)
SIL claim limit
1)
SILCL2 (EN 62061)
Category
Category 3 (ISO 13849-1)
Performance level
PL d (ISO 13849-1)
amb
= 25 °C) (mean probability of a danger‐
ous failure per hour)
8 × 10
–8
T
M
(mission time)
20 years (ISO 13849)
Laser class
Laser class 1 (according to IEC 60825-1
as well as CDRH 21 CFR 1040.10 and
1040.11; excluded are deviations due to
Laser Notice No. 50 dated June
24, 2007)
Enclosure rating
IP65 (EN 60529)
Protection class
II (EN 50178)
2)
Operating temperature range
–10 °C
+50 °C
TECHNICAL DATA
12
8013291/ZA19/2019-11-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | S3000 PROFINET IO, S3000 PROFINET IO-OF
111
Subject to change without notice