Minimum
Typical
Maximum
Scanning angle
190°
(–5° to
+185°)
Radiance factor
1.8%
Several
1,000%
(reflectors)
0.5°
0.25°
Generally necessary protective field supplement
100 mm
Supplement for retro-reflectors on scan plane with
distance of less than 1 m to protective field bound‐
ary
200 mm
Measurement error for measurement data output up to 5.5 m and 1.8% radiance factor
Systematic error
± 5 mm
Statistical including systematic error
At 1 σ
± 24 mm
At 2 σ
± 43 mm
At 3 σ
± 62 mm
At 4 σ
± 80 mm
At 5 σ
± 99 mm
Flatness of the scan field at 5.5 m
± 70 mm
Flatness of the scan field at 7 m
± 88 mm
Distance of mirror rotational axis (zero point of X-
and Y-axis) to rear side of device
93 mm
Distance between center point of scan plane and
bottom edge of the housing
63 mm
Warning field range (radial)
Approx. 20
m
2)
49 m
Distance measurement range
49 m
Number of multiple samplings (can be configured
via CDS)
2
16
Power-up delay
9 s
20 s
Restart after (can be configured)
2 s
60 s
1)
Radial distance to the safety laser scanner.
2)
For objects with 20% radiance factor.
Electric
Table 29: Electric
Minimum
Typical
Maximum
Electrical protection class
III (VDE 0106, EN 60950)
Bus connection
2 standard PROFINET IO female connec‐
tors for push-pull plug connectors with
metal housing (RJ-45 or SCRJ)
Levels for input information
Restart
1)
Activated on low-high transition
Initialization
Activated on low-high transition
Standby
Activated on permanently high
Monitoring case switching
1)
Static (complementary)
12
TECHNICAL DATA
114
O P E R A T I N G I N S T R U C T I O N S | S3000 PROFINET IO, S3000 PROFINET IO-OF
8013291/ZA19/2019-11-14 | SICK
Subject to change without notice