The response time of the safety laser scanner to input information comprises:
•
S3000 basic response time
•
+ configured input delay
•
+ response time of the I/O module (2 × 8 ms = 16 ms)
•
+ response time of the FPLC
Table 33: Calculating the response time to input information, example
60 ms basic response time (resolution = 0.5°)
+
30 ms (configured input delay)
+
16 ms
=
106 ms (+ response time of the FPLC)