Function
Advanced
Professional
Field sets comprising one protective field
and 2 warning fields (triple field mode)
with an angular resolution of 0.5°
4
8
Field sets comprising one protective field
and 2 warning fields (triple field mode)
with an angular resolution of 0.25°
4
8
Programmable monitoring cases
4
16
Static control inputs for monitoring case
switching
2
4
Output of measurement data (surrounding
contour)
✓
✓
1)
Function is available for firmware B02.43 or above.
3.2.4
Sensor heads
The sensor heads differ with regards to their maximum scanning range and the resul‐
tant protective field size.
1
2
3
Figure 5: Protective field ranges of the sensor heads
1
Short Range sensor head, maximum scanning range 4 m
2
Medium Range sensor head, maximum scanning range 5.5 m
3
Long Range sensor head, maximum scanning range 7 m
3.2.5
Status indicators
The LEDs and 7-segment display signal the operational status of the device. They are
located on the front side of the device. Above each of the LEDs is an icon that will be
used to describe the LED in these operating instructions.
PRODUCT DESCRIPTION
3
8013291/ZA19/2019-11-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | S3000 PROFINET IO, S3000 PROFINET IO-OF
17
Subject to change without notice