2.
On the
PROFIsafe
tab, configure the parameters for the S3000 PROFINET IO/IO-OF.
Figure 58: PROFIsafe configuration, step 2
NOTE
The parameters are described in
Complementary information
Table 10: PROFIsafe parameters for the S3000 PROFINET IO/IOOF
Parameter
Meaning
Setting
F_SIL
Safety integrity level (NoSIL, SIL1 or SIL2) of the
S3000 PROFINET IO/IO-OF
Depends on the
application
F_CRC_Length
Expected length of the CRC checksum in the PROFIsafe
telegram
3-byte CRC
1)
F_Block_ID
This parameter is set to 1 to indicate that the data set
for the value of F_iPar_CRC is extended by 4 bytes. You
must not change this parameter.
0
F_Par_Version
Implemented PROFIsafe version. You cannot change this
parameter.
1
F_Source_Add
PROFIsafe source address. Must be unique in combina‐
tion with the PROFIsafe destination address and is
assigned automatically.
1 to 65,534
F_Dest_Add
PROFIsafe destination address. Must be unique in com‐
bination with the PROFIsafe source address and is
assigned automatically.
•
The PROFIsafe address for the
S3000 PROFINET IO/IO-OF must match this value.
b
Enter the default value for the F_Dest_Add parame‐
ter using CDS (
).
1 to 65,534
CONFIGURATION
7
8013291/ZA19/2019-11-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | S3000 PROFINET IO, S3000 PROFINET IO-OF
71
Subject to change without notice