5.10
(only for safeRS Sensor) Connect the control to the sensors and assign the IDs
1. Decide if the control will be positioned at the end of the chain or inside of it (see
).
2. Start the application.
3. For safeRS, click
Login
and
Configuration
. For safeRS/safeRS3 mixed system, click
User
and
Configuration
.
4. Verify that the number of sensors in the configuration is the same of the sensors
installed.
5. For safeRS, click
Settings
and
Sensor ID Nodes
. For safeRS/safeRS3 mixed system,
click
Settings
and
Node ID Assignment
.
6. Set the DIP switch of the control based on its position in the chain.
7. Connect the desired sensor directly to the control.
8. Insert the termination connector (product code 6073830) in the free connector of
the sensor.
9. For safeRS, click
ASSIGN ID NODES
. For safeRS/safeRS3 mixed system, click
ASSIGN NODE IDS
and follow the instructions displayed to assign a Node ID to the
sensor.
10. To add a sensor, click
ADD NEXT SENSOR
.
11. Connect the new sensor directly to the control or to the last sensor in the chain.
12. To insert the termination connector, perform the following steps:
If the sensor has been connected…
Then…
to the control
insert a new termination connector into the
free connector of the sensor just connected.
to the last sensor in the chain
move the termination connector of the
previous sensor and insert it into the free
connector of the sensor just connected.
13. Click
PROCEED
and follow the instructions displayed to assign a Node ID to the new
sensor.
14. Repeat from step 8 to connect another sensor, or click
TERMINATE
to conclude the
procedure.
Note
: the maximum length of the CAN bus line from the control to the last sensor in the
chain is 30 m (98.4 ft).
5.11
Install safeRS3 Sensor
1. Position the sensor as indicated in the configuration report and fasten the bracket
with two screws onto the floor or another support.
N
2. With an Allen key, loosen the screw at the bottom to pan the sensor.
Note
: to avoid damaging the bracket, loosen the screw completely before panning
the sensor.
O
3. Pan the sensor until it reaches the desired position.
Note
: a notch is equal to 10° of inclination.
P