Figure 16: PROFINET configuration
Figure 17: Logic Editor
7.3.5.3
IO-Link ports
On the
IO-Link Ports
tab, settings of the IO-Link ports that can be used in IO-Link or
standard input/output mode can be configured.
An IODD file can be uploaded here for easy parameterization of the connected IO-Link
device. First upload an IODD file using the
Upload IODD
button. This IODD is then stored
in the SIG200
Repository
.
The disk usage shows how much storage capability on SIG200 is available.
After the correct IODD file has been uploaded, it can be assigned to the port to which
the corresponding device is connected (e.g. port S1). To do this, select the IODD file on
the right side of the table using the drop-down menu. All IODDs already in the
Repository
are displayed and the correct one can be selected. If an IODD is to be deleted from the
device, select the desired IODD and click
DELETE
.
After the desired IODD is selected, confirm by clicking the
Apply
button. The information
from the IODD is now displayed on the
IO-Link Devices
tab.