Properties
Value
PROFINET access
SIG200-IO-Link master (slot 2, subslot 1)
Index
0xB100 (Port S1)
0xB101 (Port S2)
0xB102 (Port S3)
0xB103 (Port S4)
Byte 14: Output data length
Coding
0…32
Number of bytes in the outgoing IO-Link device process
data
7.1.2.2.1.9
Port status information
Port status info
can be used to read out the status of the connection to an IO-Link device
on a specific IO-Link port.
Properties
Value
PROFINET access
SIG200-IO-Link master (slot 2, subslot 1)
0xB200 (Port S1)
0xB201 (Port S2)
0xB202 (Port S3)
0xB203 (Port S4)
Byte 3: Port status information
Coding
0
Port in IO-Link mode
1
Port in DI mode
2
Port in DO mode
3
Port deactivated
4
No device on the port
5
Incorrect device on the port
6
Error
255
Information temporarily unavailable
7.1.2.2.1.10
Revision ID
Revision ID
can be used to read out the IO-Link version of the IO-Link device on this port.
Properties
Value
PROFINET access
SIG200-IO-Link master (slot 2, subslot 1)
Index 0xB200/0xB201/0xB202/0xB203, byte 7: Revision ID
Coding
16
Version V1.0
17
Version V1.1
7.1.2.2.1.11
Transmission rate
With
Transmission rate
, the IO-Link data transmission rate at this port can be read out.
Properties
Value
PROFINET access
SIG200-IO-Link master (slot 2, subslot 1)
Index 0xB200/0xB201/0xB202/0xB203, byte 8: Transmission
rate
Coding
0
No communication
1
COM1
2
COM2
3
COM3
7
SIG200 CONFIGURATION
38
O P E R A T I N G I N S T R U C T I O N | Sensor Integration Gateway - SIG200
8017853.1D0S/2021-11-04 | SICK
Subject to change without notice