Chapter
5
Technical Information
TiM51x ranging laser scanner
19
©
SICK AG · Germany · All rights reserved · Subject to change without notice
8016425/YZK8/2016-07-07
Measured value output
5.2
Request measured values
After switching on the supply voltage, the TiM51x initializes and the green LED
will light
up to indicate its readiness for operation.
The TiM51x begins its readiness to measure automatically. It continuously scans the sur-
rounding contour in its field of vision at a frequency of 15 Hz. It continuously saves the val-
ues determined in each measuring process (scan) in its measured value memory by
overwriting the previous values.
5.2.1
Single measured value output
If the data from a measuring process are required, the TiM51x sends the measured values
from the most recent scan.
Example of single measured value output
Request:
<
STX
>sRN LMDscandata<
ETX
>
Answer of TiM51x:
<
STX
>sRA LMDscandata (contents see
Chapter 5.3 Measured value output fomat,
) <
ETX
>
Telegram structure:
sRN LMDscandata
Measured value request
Output of
one
measured value telegram
Telegram part
Description
Variable type Length (byte) Value range
Type of command
Request (SOPAS read by name) string
3
sRN
Command
Data request
string
11
LMDscandata