81
8015383/ZUQ7/V1-3/2020-06 | SICK
O P E R A T I N G I N S T R U C T I O N S | TRANSIC151LP
Subject to change without notice
ANNEX
11
11.3
Type code TRANSIC151LP
SICK TRANSIC Oxygen Transmitter
TRANSIC151LP-
Version
[1]
[1] NOTE: 100 vol% O
2
is not covered by ATEX/IECEx.
In-line (range 0 … 25 vol% O
2
)
with a flange adapter for in-line mounting <0.5 bar
A
Ambient environment (range 2 … 25 vol% O
2
)
with a wall mounting bracket
B
Sample cell (range 0 … 25 vol% O
2
)
with a sample cell and a wall mounting bracket PN10
C
In-line (range 0 … 25 vol% O
2
)
with a flange adapter for in-line mounting PN10
F
In-line (range 0 … 25 vol% O
2
)
with a weld adapter for in-line mounting PN10
G
In-line (range 0 … 25 vol% O
2
)
with a 3" clamp adapter for in-line mounting PN10
H
Filter type
[2]
[2] PTFE filter for wet gases near dew point not recommended.
No filter (sample cell installation)
[3]
[3] Only in case of pure gas and installation into a sample cell.
1
Stainless steel net (1.4404)
2
PTFE filter with stainless steel net
3
Analog output range for oxygen
(can be reconfigured in the field)
[4]
[4] Requires a Service Interface Cable and terminal program on PC, only when hazardous atmosphere is not present!
O
2
(0 … 5 vol%)
A
O
2
(0 … 10 vol%)
B
O
2
(0 … 15 vol%)
C
O
2
(0 … 20 vol%)
D
O
2
(0 … 25 vol%)
E
Define O
2
special range
[5]
[5] Factory default range is 0…25 vol% O
2
. Maximum can be chosen between 5 vol% and 100 vol%.
from _______vol% O
2
to _______vol% O
2
X
Signal output
(can be reconfigured in the field)
4 … 20 mA
1
0 … 20 mA
2
Fault state current for analog output
(can be reconfigured in the field)
≤
3 mA
[6]
[6] Fault state 3 mA can be chosen only if signal output is 4 … 20 mA.
A
≥
21 mA
B
Relay settings (can be reconfigured in the field)
[7] Default: 10 vol% O
2
. Hysteresis: 1 vol% O
2
.
Digital output opens ONLY when fault state occurs
1
Setpoint: _______ vol% O
2
→
Digital output opens when O2 value decreases below setpoint
X
Digital output opens when O2 value increases above setpoint
y
Digital output opens to indicate request for maintenance
4
Material of sample wetted parts
Mirror Type
Gasket material
Front face coated mirror gold
FFKM Original Kalrez® Spectrum
B
Front face coated mirror gold
FKM with BAM-Approval
C
Back face coated mirror
FFKM Original Kalrez® Spectrum
F
Back face coated mirror
FKM with BAM-Approval
G
Cable
bushings
[8]
[8] NOTE: Use SICK Ex i cable for Transmitter to TSA151 connection only! Read manual for cabling requirements!
Cable gland Ex M20x1.5
(customer wiring)
C
Cable gland Ex M20x1.5 0.5 m
(0.5 m cable Transmitter to TSA151-Unit)
D
Cable gland Ex M20x1.5 2 m
(2.0 m cable Transmitter to TSA151-Unit)
E
Cable gland Ex M20x1.5 5 m
(5.0 m cable Transmitter to TSA151-Unit)
F
Conduit fitting NPTf 1/2"
(0.5 m cable Transmitter to TSA151-Unit)
G
Conduit fitting NPTf 1/2"
(2.0 m cable Transmitter to TSA151-Unit)
H
Conduit fitting NPTf 1/2"
(5.0 m cable Transmitter to TSA151-Unit)
I
In-line calibration option
no
A
Calibration gas inlet 6 mm with check valve
[9]
[9] PTFE filter for calibration gas inlet recommended.
B
Accessories
None
1
USB Service Interface Cable for PC
[10]
[10]Only when hazardous atmosphere is not present. Use SICK Service Interface Cable only.
4
User's guide language
English
B
German
C
Spanish
D
Russian
E
French
F
Italian
G
Chinese
H
Portuguese
I
Japanese
J
Finnish
K
Calibration
ISO 9001 compliant factory calibration
1
Maintenance and repair
Standard maintenance and repair
A
Approval
ATEX / IECEx
2
TSA151
with TSA151 Power Supply Unit
(standard)
A
Example:
TRANSIC151LP- A 3 E 1 A 1 C 2 A 1 B 1 A 2 A