78
8015383/ZUQ7/V1-3/2020-06 | SICK
O P E R A T I N G I N S T R U C T I O N S | TRANSIC151LP
Subject to change without notice
10
SPECIFICATIONS
10.4.9
Dimensions and mechanics
10.4.10
Pressure suitability
10.4.11
Options and accessories
Dimensions
TRANSIC151LP transmitter
TSA151 voltage supply unit
Dimensions (H × W × D)
306 × 184 × 74 mm
3
189 × 268 × 91 mm
3
Weight
2.2 kg
3 kg
Enclosure material
G-AlSi10Mg (DIN 1725)
G-AISi12(Fe)
Enclosure classification
IP66
IP66
Flange
Can be attached to DIN/ANSI standard flanges.
Minimum flange sizes:
●
DIN EN 1092 DN50: Fitted with M16 DIN933 or similar
●
ANSI ASME B16.5 (150) 2.5": Fitted with UNC 3/4"-10 or similar
Cable bushing
Cable gland M20×1.5
Filter
●
Stainless steel mesh, holes 0.31 mm, wire thickness 0.2 mm
●
Hydrophobic PTFE filter, average pore size 8
μ
m
Materials with sample gas con-
tact
●
AISI 316L(1.4404)
●
FKM or Kalrez
®
(optional)
●
PTFE, SiN, MgF
2
, quartz glass
●
Polymer coating
For plant design
[1]
[1] Outside the measuring range (e.g., in error case); valid for transmitter, seals, sample gas cell and flange adapter
with M8 screws). Not valid for flange adapter with M5 screws (0.5 bar).
●
TS
min
: -20 °C
●
TS
max
: 80 °C
●
PS: 10 bar(g)
●
V: 0.28 L
●
DN: 50 … 65 mm (2" … 3")
NOTE:
▸
Observe local regulations with regard to pressure!
▸
Do not use the TRANSIC151LP for unstable gases (e.g., acetylene).
Hydrophobic PTFE filter
Hydrophobic PTFE filter, average pore size 0.8
μ
m
Sample gas cell volumes
Gas connections
T
90
response time with 1 l/min gas sample flow rate
Weight
V: 0.280 l
Swagelok connection for Ø 6 mm gas tubes
11 s
2.2 kg