9. RECOGNITION OF ABNORMAL OPERATION
9.2 Continuous Trickle
If you notice a continuous trickle of water from the PTR valve, this is likely due to a build up of grit
or scale. Lift the lever to release water for a few seconds from the PTR valve. This may dislodge
small particles of foreign matter to rectify the fault. It is normal for the PTR valve to release a
small quantity of water during the heating cycle. The amount of discharge will depend on hot
water usage. As a guide, if it discharges more than 20 litres of water in 24 hours then there may
be a problem.
9.4 No Hot Water
1) Check if the power is switched on. Check that the isolating switch, to which your Solarstream
is connected, is switched on. Check that the switch marked
Water Heater
on your power
switchboard is turned on. Check that all circuit breakers have been reset.
If you are connected to Off Peak or a Smart Meter, check that you have power supplied when
checking the operation of your Solarstream.
2) Check that the thermal overload (on the digital controller) has not tripped. Turn the power off
then back on to perform a reset action.
3) Check whether the Pressure & Temperature Relief valve is discharging too much water. Refer
to Section 4.4
4). Check that you have the correctly size water heater for your requirements. Sizing details are
available from your Siddons. The rule of thumb is 50 litres per person per day in winter, less in
summer.
5). Check your household water usage. Is one outlet (such as the bath) using more hot water than
you think? Review your family's hot water usage and if necessary check the shower flow rates
with a bucket and measure this. Consider installing low volume shower heads and other measures
to reduce hot water usage.
9.3 Steady Flow
If you notice a steady flow of water from the PTR valve, then this may be caused by excessive
water supply pressure. Note, a 500kPa Pressure Limiting valve must be fitted. It may also be
caused by a faulty Pressure & Temperature Relief (PTR) valve, or a faulty Thermostat / Digital
Controller. Turn off the electricity supply and contact a qualified technician or Siddons for help.
16
9.1 Start up Delay
NOTE: The heat pump has a 3-minute time delay on restart. If the power to the heat pump is cut
during its heating cycle, then a time delay period will commence upon re-start. The compressor
and fan will not operate until the completion of this delay period.
SIDDONS
AIR TO WATER HEAT PUMP WATER HEATER
AIR TO WATER HEAT PUMP WATER HEATER