7
Technical Data
Device variant
02192100IF
Mains connection
3 × 200 V to 480 V ±10 %
50 / 60 Hz
Output voltage V
AC
3 × 220 V
Output frequency f
0 to 8333 Hz
Apparent power P
S
(1)
S1
(2)
13 kVA
S6
(3)
19.2 kVA
Output phase currents I
rms
S1
33.6 A
S6
50.4 A
Internal ballast resistor
P
rated
400 W
P
pulse
for 1 s
13000 W
Efficiency η
about 0.95
Load cos φ
0.5 to 1.0 inductive
Ambient temperature Θ
0 to 40 °C
Weight m
12,8 kg
(1)
The apparent output powers have been calculated for an output voltage of 220 V
rms
.
(2)
S1: continuous load with S1 values
(3)
S6: load that is alternating between 15 s of S6 values (load) and 12 s of 40 % of S6 values (open-circuit
operation)