8.3
X3 – Bus Inputs
Female RJ45 connector
X3
Pin
I/O
Name
Meaning
1
I
CAN_H
CAN bus +
2
I
CAN_L
CAN bus -
3
I/O
D+
RS485 +
4
I/O
RX
RS232 (receive data)
5
I/O
TX
RS232 (transmit data)
6
I/O
D-
RS485 -
7
I/O
GND
Ground
8
I/O
GND
Ground
Related topics
Connection examples: "X3, X4 – Bus Connection", page 49
8.4
X4 – Bus Outputs
Female RJ45 connector
X4
Pin
I/O
Name
Meaning
1
O
CAN_H
CAN bus +
2
O
CAN_L
CAN bus -
3
I/O
D+
RS485 +
4
n.c.
5
n.c.
6
I/O
D-
RS485 -
7
I/O
GND
Ground
8
I/O
GND
Ground
Related topics
Connection examples: "X3, X4 – Bus Connection", page 49
8.5
X10 – Safety (STO)
Safety circuit and restart lock (STO)