Connector
SIEB & MEYER article number
Inputs (black)
12540102
12540103
Outputs (gray or white)
12540202
12540203
Cable connector
(TOSLINK F05)
32022900
NOTICE
Risk of cable damage
If you pull the optical fiber cable with its connector too fast out of the connector, the
cable may be damaged.
When unplugging the cable, hold the fiber optic connector and pull the cable care‐
fully out of the connector.
Related topics
Connection example: "X26/X27 – SERVOLINK", page 51
8.7.1
Preparation of Optical Fiber Cables with Connector
Every optical fiber connector requires an optical fiber cable with a male connector. The
following information apply for connectors used in applications with 1 mm standard
plastic optical fibers (POF).
Technical data
Rated value
Storage temperature
-40 to 70 °C
Operating temperature
-20 to 70 °C
Tensile stress
Between optical fiber cable and connector
19.6 N
Optical fiber cable
49 N
Bending radius
(1)
Min. 25 mm
(1)
When bending the optical fiber cable to install it, note that the recommended bending radius is six to ten
times greater than the minimum bending radius.
W
Connectors
FC2 - Frequency converter 02192100xy
35
8
Summary of Contents for FC2
Page 4: ...Chapter Overview W 4 FC2 Frequency converter 02192100xy ...
Page 8: ...Content W 8 FC2 Frequency converter 02192100xy ...
Page 12: ...General Information W 12 FC2 Frequency converter 02192100xy 2 ...
Page 22: ...Unit Assembly Complying EMC W 22 FC2 Frequency converter 02192100xy 4 ...
Page 30: ...Technical Data W 30 FC2 Frequency converter 02192100xy 7 ...
Page 48: ...Connectors W 48 FC2 Frequency converter 02192100xy 8 ...
Page 70: ...Safety Circuit Restart Lock STO W 70 FC2 Frequency converter 02192100xy 12 ...